{"product_id":"generac-xg03245anax-32kw-lc-single-phase-automatic-standby-generator","title":"Generac XG03245ANAX 32kW LC  Single Phase Automatic Standby Generator","description":"\u003cdiv class=\"a-plus-pdp-page\"\u003e\r\n  \u003cdiv class=\"pdp_hero_banner\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/Guardian_Home_Backup.png?3280\" alt=\"guardian-home-backup\"\u003e\u003c\/div\u003e\r\n  \u003cdiv class=\"pdp_leftcolumn\"\u003e\r\n      \u003cdiv class=\"pdp_downloads\"\u003e\r\n          \u003ch5\u003eProduct Downloads\u003c\/h5\u003e\r\n          \u003c!-- EDWIN - REPLACE THESE LINKS WITH PRODUCT DOCUMENTATION FOR EACH SKU START --\u003e\r\n          \u003cdiv class=\"download\"\u003e\r\n              \u003ca href=\"https:\/\/www.generac.com\/generaccorporate\/media\/library\/pdfs\/sellsheet_commercial_32-40kw_protectorseries_2023.pdf\" target=\"“_blank”\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/PDF-Icon.png?3280\" alt=\"brochure-download\"\u003e\u003c\/a\u003e\r\n              \u003cp class=\"pdp_downloads_title\"\u003eBrochure\u003c\/p\u003e\r\n          \u003c\/div\u003e\r\n          \u003cdiv class=\"download\"\u003e\r\n              \u003ca href=\"https:\/\/www.generac.com\/generaccorporate\/media\/library\/content\/all-products\/generators\/resi-comm\/protector\/a0005286945-(1).pdf\" target=\"“_blank”\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/PDF-Icon.png?3280\" alt=\"specifications-download\"\u003e\u003c\/a\u003e\r\n              \u003cp class=\"pdp_downloads_title\"\u003eSpecifications\u003c\/p\u003e\r\n          \u003c\/div\u003e\r\n          \u003cdiv class=\"download\"\u003e\r\n              \u003ca href=\"https:\/\/soa.generac.com\/manuals\/3005095743\/10000024942\" target=\"“_blank”\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/PDF-Icon.png?3280\" alt=\"manual-download\"\u003e\u003c\/a\u003e\r\n              \u003cp class=\"pdp_downloads_title\"\u003eOwner's Manual\u003c\/p\u003e\r\n          \u003c\/div\u003e\r\n          \u003cdiv class=\"download\"\u003e\r\n              \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0081\/8177\/6431\/files\/10000008140.pdf?4029\" target=\"“_blank”\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/PDF-Icon.png?3280\" alt=\"manual-download\"\u003e\u003c\/a\u003e\r\n              \u003cp class=\"pdp_downloads_title\"\u003eWi-Fi Manual\u003c\/p\u003e\r\n          \u003c\/div\u003e\r\n          \u003cdiv class=\"download\"\u003e\r\n              \u003ca href=\"https:\/\/www.generac.com\/generaccorporate\/media\/library\/content\/all-products\/generators\/resi-comm\/0l0258-rev-c-5-year-warranty.pdf\" target=\"“_blank”\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/PDF-Icon.png?3280\" alt=\"warranty-download\"\u003e\u003c\/a\u003e\r\n              \u003cp class=\"pdp_downloads_title\"\u003eWarranty\u003c\/p\u003e\r\n          \u003c\/div\u003e\r\n          \u003c!--- REPLACE THESE LINKS WITH PRODUCT DOCUMENTATION FOR EACH SKU END --\u003e\r\n      \u003c\/div\u003e\r\n      \u003cdiv class=\"pdp_additionalfeatures\"\u003e\r\n          \u003ch5\u003eFeatures\u003c\/h5\u003e\r\n          \u003c!--- THIS IS WHERE PRODUCT FEATURES\/IN THE BOX INFO STARTS --\u003e\r\n          \u003cul\u003e\r\n            \u003cli\u003ePower Zone 410 Controller, NFPA 110 Capable\u003c\/li\u003e\r\n            \u003cli\u003eCellular Connectivity for Mobile Link and Fleet\u003c\/li\u003e\r\n            \u003cli\u003eQuiet Operation\u003c\/li\u003e\r\n            \u003cli\u003eCorrosion Resistant Enclosure \u0026amp; Frame\u003c\/li\u003e\r\n            \u003cli\u003e5 Year\/2,000 Hour Limited Warranty\u003c\/li\u003e\r\n            \u003cli\u003eHi Motor Starting, Surge Capacity\u003c\/li\u003e\r\n            \u003cli\u003eFuel Efficiency\u003c\/li\u003e\r\n            \u003cli\u003eController-Selectable Fuel Type - Natural Gas or Propane Vapor\u003c\/li\u003e\r\n            \u003cli\u003e1-Phase or Configurable 3-Phase Voltage Output\u003c\/li\u003e\r\n            \u003cli\u003eSingle-Side Regular Maintenance Access\u003c\/li\u003e\r\n            \u003cli\u003eEPA \u0026amp; SCAQMD Exhaust Emissions Certified\u003c\/li\u003e\r\n            \u003cli\u003eAs close as 18 in (457 mm) offset distance from structure\u003c\/li\u003e\r\n          \u003c\/ul\u003e\r\n          \u003ch5\u003eWhat's in The Box\u003c\/h5\u003e\r\n          \u003cul\u003e\r\n                   \u003cli\u003e32kW LC Automatic Standby Generator 1-Phase- XG03245ANAX\u003c\/li\u003e\r\n            \u003cli\u003eOwners Manual\u003c\/li\u003e\r\n          \u003c\/ul\u003e\r\n          \u003ch5\u003eWarranty\u003c\/h5\u003e\r\n          \u003cul\u003e\r\n              \u003cli\u003e5-Year Limited Factory Warranty\u003c\/li\u003e\r\n              \u003cli\u003e30 Day Satisfaction Guaranteed\u003c\/li\u003e\r\n          \u003c\/ul\u003e\r\n          \u003c!--- THIS IS WHERE PRODUCT FEATURES\/IN THE BOX INFO ENDS --\u003e\r\n      \u003c\/div\u003e\r\n      \u003cdiv class=\"pdp_imagery\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/True_Power_Tech.png?3280\" alt=\"true-power-technology\"\u003e\u003c\/div\u003e\r\n  \u003c\/div\u003e\r\n  \u003cdiv class=\"pdp_rightcolumn\"\u003e\r\n      \u003cdiv class=\"product-video\"\u003e\u003ciframe width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/LRrGscxU58c\" frameborder=\"0\" allow=\"accelerometer; autoplay; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen=\"\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\r\n      \u003cdiv class=\"product-specs\"\u003e\r\n          \u003ch5\u003eSpecifications\u003c\/h5\u003e\r\n          \u003c!--- THIS IS WHERE SPECIFICATION TABLE STARTS --\u003e\r\n          \u003ctable\u003e\r\n              \u003ctbody\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eSKU\u003c\/td\u003e\r\n                  \u003ctd\u003eXG03245ANAX\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n              \u003ctr\u003e\r\n                  \u003ctd\u003eBrand\u003c\/td\u003e\r\n                  \u003ctd\u003eGenerac\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd colspan=\"2\"\u003eGenerator Output\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd rowspan=\"3\"\u003eVoltage\u003c\/td\u003e\r\n                  \u003ctd colspan=\"4\"\u003eXG03245\u003c\/td\u003e\r\n                  \u003ctd colspan=\"4\"\u003eXG04045\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd colspan=\"4\"\u003eNatural Gas\u003c\/td\u003e\r\n                  \u003ctd colspan=\"4\"\u003eLiquid Propane\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd colspan=\"2\"\u003ePower (kW)\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eCurrent (A)\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003ePower (kW)\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eCurrent (A)\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003e120\/240 1–Phase\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e133\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e133\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e139\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003e208\/120 3–Phase\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e111\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e111\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e120\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003e240\/120 3–Phase\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003e480\/277 3–Phase\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e32\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e40\u003c\/td\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd colspan=\"2\"\u003eVoltage Regulation\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eType\u003c\/td\u003e\r\n                  \u003ctd\u003eElectronic\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eSensing\u003c\/td\u003e\r\n                  \u003ctd\u003eAll Phases\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eRegulation\u003c\/td\u003e\r\n                  \u003ctd\u003e+- 1 percent\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd colspan=\"2\"\u003eGovernor Specifications\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eType\u003c\/td\u003e\r\n                  \u003ctd\u003eElectronic\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eFrequency Regulation\u003c\/td\u003e\r\n                  \u003ctd\u003eIsochronous\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eSteady State Regulation\u003c\/td\u003e\r\n                  \u003ctd\u003e+- 25 percent\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd colspan=\"2\"\u003eAlternator System Specifications\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eXG03245\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eXG04045\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003e\u003c\/td\u003e\r\n                  \u003ctd\u003e1-Phase\u003c\/td\u003e\r\n                  \u003ctd\u003e3-Phase\u003c\/td\u003e\r\n                  \u003ctd\u003e1-Phase\u003c\/td\u003e\r\n                  \u003ctd\u003e3-Phase\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eVoltage Output\u003c\/td\u003e\r\n                  \u003ctd\u003e120\/240 V Only\u003c\/td\u003e\r\n                  \u003ctd\u003e208\/120 V; Configurable for 480\/277 or 240\/120 V with Optional Field-Installable VCC\u003c\/td\u003e\r\n                  \u003ctd\u003e120\/240 V Only\u003c\/td\u003e\r\n                  \u003ctd\u003e208\/120 V; Configurable for 480\/277 or 240\/120 V with Optional Field-Installable VCC\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eCircuit Breaker (CB) Size\u003c\/td\u003e\r\n                  \u003ctd\u003e150 A\u003c\/td\u003e\r\n                  \u003ctd\u003eNot Included; Optional Field-Installable Kit\u003c\/td\u003e\r\n                  \u003ctd\u003e200 A\u003c\/td\u003e\r\n                  \u003ctd\u003eNot Included; Optional Field-Installable Kit\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eType\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eSynchronous\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eSynchronous\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eRotor Insulation Class\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eF\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eF\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eStator Insulation Class\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eH\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eH\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eTelephone Interference Factor (TIF)\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003e\u0026lt; 50\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003e\u0026lt; 50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eBearings\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eSealed Ball\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eSealed Ball\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eCoupling\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eFlexible Disc\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eFlexible Disc\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                  \u003ctd\u003eExcitation System\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eDirect\u003c\/td\u003e\r\n                  \u003ctd colspan=\"2\"\u003eDirect\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd colspan=\"2\"\u003eEngine Specifications\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e\u003c\/td\u003e\r\n  \u003ctd\u003eXG03245\u003c\/td\u003e\r\n  \u003ctd\u003eXG04045\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eMake\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eGenerac\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eModel\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eInline 4 Cylinder\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eCylinders\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e4\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eDisplacement (L)\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e4.5\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eBore\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e4.5 in\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eStroke\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e4.25 in\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eCompression Ratio\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e9.9:1\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eLifter Type\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eHydraulic\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eIntake Air System\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eNaturally Aspirated\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eTemperature Derate\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e1.5% per every 5°C above 25°C (1.65% per every 10°F above 77°F)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eAltitude Derate\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e1% per every 100 m above 183 m (3% per every 1000 ft above 600 ft)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eExercise Speed (RPM)\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e1,200\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eOperating Speed (RPM)\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e1,800\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd colspan=\"2\"\u003eCooling System\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e\u003c\/td\u003e\r\n  \u003ctd\u003eXG03245\u003c\/td\u003e\r\n  \u003ctd\u003eXG04045\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eCoolant\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e50\/50 (50% Ethylene Glycol)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eCoolant System Capacity (L (US gal))\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e11 (2.9)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eWater Pump\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eBelt–Driven\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eFan Type\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eMechanical\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eFan Quantity\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e1\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eMaximum Ambient Air Temperature (C (F))\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e50 (122)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd colspan=\"2\"\u003eFuel Types\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e\u003c\/td\u003e\r\n  \u003ctd\u003eXG03245\u003c\/td\u003e\r\n  \u003ctd\u003eXG04045\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eNatural Gas\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eNG Pressure (kPa (in. WC))\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e0.87 – 3.48 (3.5 – 14)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eLiquid Propane\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eLP Vapor Pressue (kPa (in. WC))\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003e1.74 – 3.48 (7–14)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eFuel Type Configuration\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eController-Selected\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eFuel Shutoff Solenoid\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eStandard, Dual\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd colspan=\"2\"\u003eFuel Consumption\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd rowspan=\"3\"\u003eRated Load\u003c\/td\u003e\r\n  \u003ctd colspan=\"4\"\u003eXG03245\u003c\/td\u003e\r\n  \u003ctd colspan=\"4\"\u003eXG04045\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd colspan=\"2\"\u003eNatural Gas\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eLiquid Propane\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eNatural Gas\u003c\/td\u003e\r\n  \u003ctd colspan=\"2\"\u003eLiquid Propane\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e(m3\/h)\u003c\/td\u003e\r\n  \u003ctd\u003e(CFH)\u003c\/td\u003e\r\n  \u003ctd\u003e(m3\/h)\u003c\/td\u003e\r\n  \u003ctd\u003e(CFH)\u003c\/td\u003e\r\n  \u003ctd\u003e(m3\/h)\u003c\/td\u003e\r\n  \u003ctd\u003e(CFH)\u003c\/td\u003e\r\n  \u003ctd\u003e(m3\/h)\u003c\/td\u003e\r\n  \u003ctd\u003e(CFH)\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e25%\u003c\/td\u003e\r\n  \u003ctd\u003e4.8\u003c\/td\u003e\r\n  \u003ctd\u003e169\u003c\/td\u003e\r\n  \u003ctd\u003e8.3\u003c\/td\u003e\r\n  \u003ctd\u003e2.2\u003c\/td\u003e\r\n  \u003ctd\u003e5.2\u003c\/td\u003e\r\n  \u003ctd\u003e184\u003c\/td\u003e\r\n  \u003ctd\u003e10\u003c\/td\u003e\r\n  \u003ctd\u003e2.6\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e50%\u003c\/td\u003e\r\n  \u003ctd\u003e6.8\u003c\/td\u003e\r\n  \u003ctd\u003e240\u003c\/td\u003e\r\n  \u003ctd\u003e12.9\u003c\/td\u003e\r\n  \u003ctd\u003e3.4\u003c\/td\u003e\r\n  \u003ctd\u003e8.2\u003c\/td\u003e\r\n  \u003ctd\u003e289\u003c\/td\u003e\r\n  \u003ctd\u003e14.5\u003c\/td\u003e\r\n  \u003ctd\u003e3.8\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e75%\u003c\/td\u003e\r\n  \u003ctd\u003e9.5\u003c\/td\u003e\r\n  \u003ctd\u003e335\u003c\/td\u003e\r\n  \u003ctd\u003e15.8\u003c\/td\u003e\r\n  \u003ctd\u003e4.2\u003c\/td\u003e\r\n  \u003ctd\u003e11.1\u003c\/td\u003e\r\n  \u003ctd\u003e392\u003c\/td\u003e\r\n  \u003ctd\u003e17.7\u003c\/td\u003e\r\n  \u003ctd\u003e4.7\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003e100%\u003c\/td\u003e\r\n  \u003ctd\u003e11.5\u003c\/td\u003e\r\n  \u003ctd\u003e406\u003c\/td\u003e\r\n  \u003ctd\u003e18.5\u003c\/td\u003e\r\n  \u003ctd\u003e4.9\u003c\/td\u003e\r\n  \u003ctd\u003e14\u003c\/td\u003e\r\n  \u003ctd\u003e494\u003c\/td\u003e\r\n  \u003ctd\u003e21.7\u003c\/td\u003e\r\n  \u003ctd\u003e5.7\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd colspan=\"2\"\u003eElectrical System\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eSystem Voltage\u003c\/td\u003e\r\n  \u003ctd\u003e12\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eBattery Charge Alternator (A)\u003c\/td\u003e\r\n  \u003ctd\u003e37\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eBattery Charger (A)\u003c\/td\u003e\r\n  \u003ctd\u003e5\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eRecommended Battery (not included)\u003c\/td\u003e\r\n  \u003ctd\u003eGroup 27R, 725 CCA Minimum\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\u003ctr\u003e\r\n  \u003ctd\u003eMaximum Allowable Battery\u003c\/td\u003e\r\n  \u003ctd\u003eGroup 31R\u003c\/td\u003e\r\n\u003c\/tr\u003e\r\n\r\n\r\n\r\n\r\n              \u003c\/tbody\u003e\r\n          \u003c\/table\u003e\r\n          \u003c!--- THIS IS WHERE SPECIFICATION TABLE ENDS --\u003e\r\n      \u003c\/div\u003e\r\n  \u003c\/div\u003e\r\n  \u003cdiv class=\"generac-benefits\"\u003e\r\n      \u003c!--- CHANGE THIS TITLE TO MATCH THE WATTAGE OF EACH SKU START --\u003e\r\n      \u003cdiv class=\"generac-benefits-title\"\u003eGENERAC GUARDIAN SERIES 20KW GENERATOR \u003cstrong\u003eFEATURES AND BENEFITS\u003c\/strong\u003e\r\n      \u003c\/div\u003e\r\n      \u003c!--- CHANGE THIS TITLE TO MATCH THE WATTAGE OF EACH SKU END --\u003e\r\n      \u003cdiv class=\"generac-benefits-info\"\u003eThis generator provides essential circuit power protection for your home during a power outage, ensuring that essential appliances maintain power. This standby generator is automatic and offers protection year-round, for less than the cost of central air conditioning.\u003c\/div\u003e\r\n      \u003cdiv class=\"pdp_leftcolumn\"\u003e\r\n          \u003cdiv class=\"generac-benefits-info\"\u003eEvery Guardian Series home standby generator comes with \u003cstrong\u003eMobile Link™ Remote Monitoring\u003c\/strong\u003e. Remote Monitoring is \u003cstrong\u003eFREE\u003c\/strong\u003e, and allows you to monitor the status of your generator from anywhere in the world. Use a smartphone, PC, or tablet to access generator information, such as the current operating status and maintenance alerts. By connecting your account you have access to authorized service dealers for fast, friendly, and proactive service.\u003c\/div\u003e\r\n          \u003cdiv class=\"generac-benefits-info\"\u003eGenerac generators are ideal for weathering storms and power outages. Their automatic backup power gives you \u003cstrong\u003epiece of mind\u003c\/strong\u003e that your home and appliances are protected.\u003c\/div\u003e\r\n          \u003cdiv class=\"generac-benefits-info\"\u003eGenerac generators and engines are designed, engineered and assembled in the USA using domestic and foreign parts.\u003c\/div\u003e\r\n          \u003cdiv class=\"generac-benefits-info\"\u003e\r\n              \u003cstrong\u003eThe Generac G-Force Engine\u003c\/strong\u003e is built to handle the stressors of generator use. This results in power that’s \u003cstrong\u003emore reliable and requires less routine maintenance\u003c\/strong\u003e than competitor engines. Generac’s new G-Force engine is purpose built and pressure-lubricated. It features hydraulic lifters, which improve engine performance and extending the life of the product. (Hydraulic lifters only available on the 13 \u0026amp; 16 kW.)\u003c\/div\u003e\r\n      \u003c\/div\u003e\r\n      \u003cdiv class=\"pdp_rightcolumn\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0066\/9030\/8211\/files\/Gen-Switch.png?3280\" alt=\"generac-standby-generator\"\u003e\u003c\/div\u003e\r\n  \u003c\/div\u003e\r\n\u003c\/div\u003e","brand":"Generac","offers":[{"title":"Default Title","offer_id":42000039510152,"sku":"GNC-XG03245ANAX","price":20679.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0074\/1176\/1270\/files\/GNC-XG03245ANAX_1.jpg?v=1712013268","url":"https:\/\/max-tools.shop\/products\/generac-xg03245anax-32kw-lc-single-phase-automatic-standby-generator","provider":"Max-tools","version":"1.0","type":"link"}